Lesson 14: Pulse-Width Modulation (PWM)

Pulse-Width Modulation (PWM)

 

Pulse-Width Modulation — What is it?

The good definition of Pulse-Width Modulation (PWM) is already in the name itself. It means modulating/varying the width of the pulse only, not the frequency. In the digital control system, PWM is used to control the amount of power sent to a device. Therefore, the PWM is a very effective technique for controlling analog devices using the digital outputs of microcontroller. It is widely used in many fields, such as measurement, communication, power control and transformation.

Principle

A PWM signal consists of two main components that define its behavior: a duty cycle and a frequency.

DutyCycle s

  • Duty Cycle
    The duty cycle describes the amount of time the signal is in a high (on) state as a percentage of the total time of it takes to complete one cycle. A lower duty cycle corresponds to lower power, because the power is off for most of the time. Duty cycle is expressed percent, 100% duty cycle would be fully on as same as setting the signal to Vcc (high); 0% duty cycle would be the same as grounding the signal.
  • Frequency
    The frequency determines how fast the PWM completes a cycle, ie. 100Hz would be 100 cycles per second. Another words, it shows how fast the PWM switches between high and low states.

In the digital system, PWM is the method to produce variable voltage using digital means. Typically, digital system only has two output voltages, the high (5V, 3.3V … etc.) or low (0V). But, how it is possible that digital system can produce a voltage that is between the high and low voltages? Here, we use mathematic to analyze the PWM signal and the average output.

Mathematical Analysis of PWM signal

PWM uses a rectangular pulse wave whose pulse width is modulated resulting in the variation of the average value of the waveform. Consider a waveform such as shown in figure 2.

PWMSignal sFigure 2: A Pulse Wave

The pulse signal is f(t) with period T and a duty cycle D (0.0~1.0). The average voltage of the waveform is given by:

\bar y = \frac{1}{T}\int_0^T {f(t)dt}

Just focus on one cycle T, as f(t) is a pulse wave, its positive pulse is for 0 < t < D×T and zero pulse is for D×T < t < T. The above expression then becomes:

\begin{array}{l}
\bar y = \frac{1}{T}\left( {\int_0^{DT} {1\;dt}  + \int_{DT}^T {0\;dt} } \right)\\
\quad  = \frac{1}{T}\left[ {DT \times 1 + T(1 - D) \times 0} \right]\\
\quad  = D
\end{array}

From this, it is obvious that the average value of the signal is directly dependent on the duty cycle D.

For example, if a digital signal produces pulse high (5V) and low (0V) equally, let us assume the signal in high state for 1 microsecond and in low state for 1 microsecond. The duty cycle is 50%, so the average voltage would be 2.5 volts. Now, change the high voltage in high state for 7 microseconds and in low state for 3 microseconds. The duty cycle now is became to 70%, the average voltage would measure 70% of 5 volts, or 5v x 0.7 = 3.5 volts.


Types of PWM

There are a couple types of PWM, and it can be classified in different ways.

Classify PWM Signal by Methods: Symmetric and Asymmetric

There are two kinds of PWM signals: Symmetric and Asymmetric.

  1. Symmetric PWM:
    • The pulses of a symmetric PWM signal are always symmetric with respect to the center of each PWM period.
    • Symmetric PWM are often used for three-phase AC induction and brushless DC motors, due to the lower harmonic distortion that is generated on phase currents in comparsion to asymmetric PWM methods.
  2. Asymmetric PWM:
    • The pulses of an asymmetric PWM signal always have the same side aligned with one end of each PWM period.
    • Asymmetric PWM can be used for stepper motors and other variable-reluctance motors.

SymmetricAsymmetricPWM s
Figure 3: Three Types of PWM Signal: Center-Aligned, Left-Aligned, and Right-Aligned PWMs

Classify PWM Signal by Signal-Alignment

The PWM signal can be classified by signal-alignment in four different types:

  1. Center-aligned PWM:
    • Symmetric PWM
    • Center-aligned PWMs are most often used in AC motor control to maintain phase alignment
  2. Left-aligned PWM
    • Asymmetric PWM
    • Left-aligned PWMs are used for most general-purpose PWM uses
  3. Right-aligned PWM
    • Asymmetric PWM
    • Right-aligned PWMs are typically only used in special cases that require alignment opposite of left-aligned PWMs
  4. Dual-edge PWM
    • Dual-edged PWMs are optimized for power conversion where phase alignment must be adjusted

 


Generating PWM with Microcontroller using Timer/Counter

The basic idea to generate PWM signal is using a counter (or timer), a CMP (compare) value, and a digital output pin. The counter continuously counts to up or down, and is compared with CMP value. The digital output (PWM) will be changed when the counter matches the CMP value, or when counter resets. It can be implemented by software or hardware. Most of microcontrollers already have hardware modules that can generate PWM signal after initialize the registers.

PWMGenertor 1 s

PWM Timer

The PWM timer in the microcontroller runs in one of two modes: Count-Down mode or Count-Up/Down mode.

  • In Count-Down mode, the timer counts from the Period (LOAD) value to zero, goes back to the Period (LOAD) value, and continues counting down.
  • In Count-Up/Dow mode, the timer counts from zero up to the Period (LOAD) value, back down to zer, back up to the Period (LOAD) value, and so on.

Generally, Count-Down mode is used for generating left- or right-aligned PWM signals, while the Count-Up/Down mode is used for generating center-aligned PWM signals.

Check the microcontroller's datasheet about PWM timer. Most of ARM microcontrollers use Count-Down mode.

Reference:

https://electronics.stackexchange.com/questions/34444/how-to-generate-a-pwm-signal-that-varies-atleast-20times-between-0-5v-range-usin

 


Go to top